The application of the medium controlled re-circulation valve is to protect the pump against
damage during low load. Automatically the bypass opens when the flow through the pump
reaches a minimum flow. The medium will be bypassed to prevent the condensate from heating up, which would lead to cavitation. Therefore, the minimum flow valve has the function of a pump safety valve. |
|

|
Design
characteristics: |
| - |
maintenance friendly due to easily
exchangeable internals |
| - |
Few wear parts |
| - |
no cavitations due to safe pressure
reduction in the bypass line. |
| - |
Customised design according to the pump specification |
 |
| Three functions in one valve! |
| - |
Non return function for pump protection |
| - |
Recirculation flow for low load |
| - |
Pressure reduction in the bypass line |
|
|